Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Include a reference to module HBOPINIT in your PLT initialization (second phase).  
  2. (Re)assemble the PLT initialization module and linkedit it into a library that your CICS will have access to.

Create the PLT

...

Shutdown Module

  1. Include a reference to module HBOPTERM in your PLT terminationshutdown  
  2. (Re)assemble the PLT termination shutdown module and linkedit it into a library that your CICS will have access to.

...

  1. In your CICS startup deck, include the library HTAC.V18.LIBRARY in your DFHRPL concatenation.  

    Note

    If you already have HostBridge installed, the library should be included after the existing reference to the HostBridge library in the DFHRPL concatenation.

  2. In your CICS startup deck, include a DD statement as follows: //HBPARMS  DD   DSN=HTAC.V18.PARMLIB,DISP=SHR; this PARMLIB will provide HTAC with access to your license key and initiallization member.. 
  3. In your CICS startup deck, include a DD statement as follows: //HBSTART  DD  SYSOUT=*; this will allow for the display of HTAC trace entries if required.
  4. In your SIT, ensure that you are running CICS monitoring.  Sample entries are: 
    • MCT=xx (where xx is the suffix for the assembled monitoring control table)
    • MN=ON
    • MNCONV=YES (or NO)
    • MNEXC=ON
    • MNPER=ON
    • MNRES=ON
  5. In your SIT, ensure that you are pointing to a PLT initialization module that contains a reference to module HBOPINIT (PLTPI=xx)..  
  6. In your SIT, ensure that you are pointing to a PLT shutdown module that contains a reference to module HBOPTERM (PLTSD=xx).
  7. Recycle your target CICS.

...